  1. Remove the Impeller: Begin by unscrewing the impeller clockwise. Note that this is a reverse thread.

  2. Detach the Nut and Silicone Washer: Carefully remove the nut and the silicone washer from the shaft.

  3. Insert the Shaft: Place the shaft through the lid and turn it until you hear a click, indicating it is securely in place.

  4. Reattach the Silicone Washer and Nut: Replace the silicone washer and nut. Tighten them by hand or use pliers for a gentle fit.

  5. Reinstall the Impeller: Attach the impeller back to the shaft and lightly tighten it using a screwdriver in a counterclockwise direction.

  6. Replace the NanoScreen: Finally, ensure the NanoScreen is appropriately positioned.