How to Calibrate Your Subscale by Subminimal
A step-by-step guide to calibrating your Subscale for accurate measurements.

How to Calibrate Your Subscale by Subminimal

Calibrating your Subscale is essential for ensuring accurate measurements, especially when precision is key. Follow this simple guide to calibrate your Subscale effectively.

Step-by-Step Calibration Process

  1. Turn on the Subscale: Begin by turning on your Subscale. As soon as the Subminimal logo starts flashing, quickly press the button four times and hold it down. This action must be completed while the logo is still flashing. If done correctly, a random number will appear on the screen without any decimal separator.

  2. Enter Calibration Mode: Tap the button again to enter calibration mode, and the word "CAL" will be displayed.

  3. Add 20g Weight: Place a 20g weight on the scale. This step is crucial for the initial calibration.

  4. Remove and Add 50g Weight: After the 20g weight is recognized, remove it and place a 50g weight on the scale. This ensures the scale is calibrated for a broader range of weights.

  5. Completion: Once the calibration is successful, the screen will display "PAS," indicating the process is complete.

For more detailed instructions and support, visit the Subminimal Quick Start Guide.

Why Calibration is Important

Regular calibration of your Subscale ensures that you get precise measurements every time, which is vital for achieving consistent results in your projects. Whether you're a barista perfecting your coffee brew or a scientist conducting experiments, accuracy is paramount.

For further assistance, explore the Subminimal HelpDesk or contact their support team for personalized help.